Processorius Schneider 140CPU31110 Unity, suggestus automationis Modicon Quantum, Modbus Plus, memoria RAM 548kB, 66MHz
Descriptio
Fabricatio | Schneider |
Modellum | 140CPU31110 |
Informationes de ordinatione | 140CPU31110 |
Catalogus | Quantum 140 |
Descriptio | Processorius Schneider 140CPU31110 Unity, suggestus automationis Modicon Quantum, Modbus Plus, memoria RAM 548kB, 66MHz |
Origo | Francogallica (Francia) |
Codex HS | 3595861133822 |
Dimensio | 5cm * 16.5cm * 31cm |
Pondus | 0.5kg |
Detalia
Series Producti | Modicon Quantum suggestum automationis |
---|---|
Typus Producti vel Componentis | Processorius Unity |
Frequentia horologii | 66 MHz |
---|---|
Numerus spatiorum | 16 4 10 2 6 |
Numerus cratium | 2 - localis |
Numerus stationum I/O distributarum | 63 1 3 Modbus Plus |
Numerus stationum I/O remotarum | 31 - 2 S908 I/O remota 0 - 0 E/S remota ethernet |
Numerus discretus I/O | Infinitus (maxime XXVII spatia) - localis 31744 ingressus, 31744 egressus - remoti 8000 ingressus, 8000 egressus - distributi - per reticulum Modbus Plus |
Numerus analogus I/O | Infinitus (maxime XXVII spatia) - localis 500 ingressus, 500 egressus - distributi - per reticulum Modbus Plus 1984 ingressus, 1984 egressus - S908 I/O remota |
I/O propriae applicationis | Ingressus interruptionis celeris Computor Accurata temporis signatio Nexus serialis |
Numerus modulorum optionalium | 2 Aethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
Numerus maximus connexionum | 1 USB 2 AS-Interface - distributa 2 Ethernet TCP/IP - localis 2 Modbus Plus - localis 2 Modbus RS232/485 Modbus/ASCII) 2 Profibus DP - localis 4 AS-Interface - remota |
Typus nexus integrati | 1 Modbus Plus 2 Modbus |
Schedulae | Moderatio processus |
Descriptio memoriae | Memoria interna 548 kB |
Functio Commutatoris | Portus communicationis commutatoris cursorii: ASCII/RTU/Memoria Interruptor portae memoriae/exstinctio |
Structura applicationis | 1 munus magistrale cyclicum/periodicum - 1 opus celeriter periodicum - XVI officia interruptionis temporis - 64 officia interruptionis I/O - 64 interruptiones officiorum - Nullum opus auxiliare - |
Tempus exsecutionis per instructionem | 0.1...0.27 µs puncta fluitantia 0.1...0.27 µs in arithmetica puncti fixi 0.12...0.585 µs Booleanum 0.12...0.585 µs in verbo |
Numerus instructionum per ms | 1.86 Kinst/ms 100% Booleanum 2.49 Kinst/ms 65% Boolean et 35% numeralis |
Summa systematis | Munus celeritatis 0.2 ms Munus magistrale 1 ms |
Currentis requisitum autobus | 1800 mA |
Signatio localis | pro communicationibus activis in portu Modbus Plus (Modbus Plus) 1 LED (viridis) pro communicationibus activis in portu Modbus (Modbus) 1 LED (viridis) CPU incepta est et logicam solvit (RUN) 1 LED (viridis) pro CPU probationes diagnosticas accensionis superavit (PARATUS) 1 LED (viridis) pro memoria scribenda (portu memoriae) 1 LED (aurantiacum) si pila substituenda est vel non adest (PILA LOW) 1 LED (rubra) pro errore communicationis in portu Modbus Plus (ERROR A) 1 LED (ruber) |
Nexus electricus | 1 connector femina SUB-D 9 ad coniunctionem cum rete Modbus Plus Duo connectores feminei SUB-D 9 ad coniungendum cum bus Modbus |
Certificationes Productarum | CSA CE UL |
---|---|
Normae | HazLoc |
Categoria | US1PC2118150 |
---|---|
Index Discountorum | PC21 |
GTIN | 3595862067300 |
Reditus | No |