Processorius Schneider 140CPU65150 Unity, suggestus automationis Modicon Quantum, Modbus Plus, memoria RAM 768kB, 166MHz
Descriptio
| Fabricatio | Schneider |
| Modellum | 140CPU65150 |
| Informationes de ordinatione | 140CPU65150 |
| Catalogus | Quantum 140 |
| Descriptio | Processorius Schneider 140CPU65150 Unity, suggestus automationis Modicon Quantum, Modbus Plus, memoria RAM 768kB, 166MHz |
| Origo | Francogallica (Francia) |
| Codex HS | 3595861133822 |
| Dimensio | 11cm * 18cm * 32cm |
| Pondus | 1.43kg |
Detalia
| Series productorum | Modicon Quantum suggestum automationis |
|---|---|
| Genus producti vel componentis | Processorius Unity |
| Frequentia horologii | 166 MHz |
|---|---|
| Numerus spatiorum | 10 16 6 4 2 |
| Numerus cratium | 2 - receptacula localia |
| Numerus stationum I/O distributarum | 63 stationes - 1 armarium - 3 retia Modbus Plus |
| Numerus stationum I/O remotarum | 31 - 2 armarium(es) per S908 I/O remotum 31 - 2 armarii per ethernet Quantum remotum I/O 16 - 2 armarii per Ethernet X80 remotum I/O |
| Numerus discretus I/O | 31744 ingressus, 31744 egressus - remoti 8000 ingressus, 8000 egressus - distributi - per reticulum Modbus Plus Infinitus (maxime 26 spatia) - localis Infinita (31 guttis 28 locorum maximum) - E/S remota ethernet |
| Numerus analogus I/O | 500 ingressus, 500 egressus - distributi - per reticulum Modbus Plus 1984 ingressus, 1984 egressus - S908 I/O remota Infinitus (maxime 26 spatia) - localis Infinita (31 guttis 28 locorum maximum) - E/S remota ethernet |
| I/O propriae applicationis | Accurata temporis signatio Nexus serialis Ingressus interruptionis celeris Computor |
| Servitium communicationis | Iter Ethernet |
| Numerus modulorum optionalium | 6 (Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
| Numerus maximus connexionum | 1 USB 2 AS-Interface - distributa 4 AS-Interface - remota 6 Ethernet TCP/IP - localis 6 Modbus Plus - localis 6 Profibus DP - localis 1 Modbus (RS232/485 Modbus/ASCII) |
| Typus nexus integrati | 1 Modbus Plus cum 1 Ethernet TCP/IP cum 1 Modbus cum 1 USB cum |
| Schedulae | Moderatio processus |
| Descriptio memoriae | Amplificabilis 7168 kB - programma cum scheda PCMCIA Amplificabilis 8 MB - memoria fasciculorum cum scheda PCMCIA Memoria interna 768 kB |
| Functio commutationis | Clavis commutatoris portae memoriae activatae/exactivatae |
| Structura applicationis | 1 munus magistrale cyclicum/periodicum - 1 opus celeriter periodicum - 128 officia interruptionis I/O - 128 interruptiones munera - XXXII officia interruptionis temporis - Quattuor officia auxiliaria - |
| Numerus instructionum per ms | 10.28 Kinst/ms 100% Booleanum 10.07 Kinst/ms 65% Boolean et 35% numeralis |
| Summa systematis | 0.2 ms pro opere celeri 1 ms pro munere principali |
| Currentis requisitum autobus | 2160 mA |
| Signatio localis | 1 LED (viridis) pro actione Ethernet (COM) 1 LED (rubra) pro collisione Ethernet |
| Nexus electricus | 1 coniunctor femina, genus coniunctoris: SUB-D 9 ad coniungendum cum rete Modbus Plus 1 coniunctor, genus coniunctoris: RJ45 ad retiaculum Ethernet connectendum 1 coniunctor, genus coniunctoris: RJ45 ad coniungendum Modbus bus |
| Certificationes productorum | Miscellanea (Marina) UL CE CSA GOST |
|---|---|
| Normae | HazLoc |