vexillo_paginae

producta

Woodward 5441-691 16 Canalium Relay FTM

brevis descriptio:

Numerus item: 5441-691

marca: Woodward

pretium: $6000

Tempus traditionis: In promptu

Solutio: T/T

portus navicularius: Xiamen


Detalia Producti

Etiquettae Productarum

Descriptio

Fabricatio Woodward
Modellum 5441-691
Informationes de ordinatione 5441-691
Catalogus MicroNet Moderatio Digitalis
Descriptio Woodward 5441-691 16 Canalium Relay FTM
Origo Civitates Foederatae Americae (US)
Codex HS 85389091
Dimensio 16cm * 16cm * 12cm
Pondus 0.8kg

Detalia

Temperatura Operativa pro MicroNet Moderatione utens CPU 68040/060: 0 ad +55°C (+32 ad +131°F), utens CPU 68040/060, aere tranquillo, nullis oneribus caloris externis. Lloyd's: ENV 1.

Temperatura Operandi pro MicroNet Moderatione utens CPU NT: 0 ad +50°C (+32 ad +122°F), cum fluxu aeris mobili ut a ventilatoribus MicroNet praebetur.

Temperatura Operativa pro MicroNet Plus Moderation utens CPU 5200: 0 ad +55°C (+32 ad +131°F), cum fluxu aeris mobili ut a ventilatoribus MicroNet praebetur.

Temperatura repositionis –40 ad +105 °C (–40 ad +221 °F) (excepto modulo CPU: –20 ad +45 °C (–4 ad +113 °F) ad vitam pilae horologii temporis realis amplificandam). [CPU NT: –40 ad +85 °C (–40 ad 185 °F)] Vita componentium adverse afficitur ab ambitus temperaturae altae et humiditatis altae. Repositio in temperatura cubiculi commendatur ad longam vitam. Si unitas diu reponenda est, potentia operativa per aliquot horas adhibenda est saltem semel singulis 18-24 mensibus. Humiditas (MicroNet) Specificatio Probationis Registri Lloyd No. 1, 1996, Probatio Humiditatis 2 (2 cycli 20–55 °C ad 95% RH non condensantes, per 48 horas, accensus ad finem non condensandi) EN 50178 (96 horae @ 93 +2 -3% RH @ 40 °C (104 F)) Humiditas (MicroNet Plus) Specificatio Probationis Registri Lloyd No. 1, 2002, Probatio Humiditatis 2 (2 cycli 20–55 °C ad 95% RH non condensantes, per 48 horas, accensus ad finem non condensandi) EN 50178 (96 horae @ 93 +2 -3% RH @ 40 °C (104 F)) Vibratio (MicroNet) Specificatio Probationis Registri Lloyd No. 1, 1996, Probatio Vibrationis 1 (5–13.2 Hz, ±1 mm; 13.2–100 Hz, ±0.7 g) EN 50178 probatio vibrationis 1 (10–57 Hz @ 0.075 mm amplitudine et 57–150 Hz @ 1 g, 10 motus per axem ad 1 octavam/minutum) Vibratio (MicroNet Plus) Lloyd's Register Test Specification No. 1, 2002, Probatio Vibrationis 1 (3–16 Hz, ±1 mm; 16–100 Hz, ±1.0 g) EN 50178 probatio vibrationis 1 (10–57 Hz @ 0.075 mm amplitudine et 57–150 Hz @ 1 g, 10 motus per axem ad 1 octavam/minutum) Impetus US MIL-STD-810C, Figura 516.2-1 ratio 1b (15 g 11 ms pulsus semi-sinusoidali) Qualitas Aeris Gradus Pollutionis 2 Altitudo (max.) 4000 m Aestimatio Supertensionis Categoria II Tutela Ingressus Secundum requisita IP20 ut definitum est in IEC 529, nisi in involucro protectivo collocatum. Livello Soni Minus quam 70 dBA Pondus MicroNet Simplex et MicroNet Plus I/O Pondus Chassis (variat cum modulo, et fortasse 2 homines requiruntur ad tuto elevandum): 22 kg (48 lb.) MicroNet TMR/5009 Fons Potentiae Principalis Pondus Chassis (variat cum modulo): 8 kg (17 lb.) Sustentatio Dielectrica Fons potentiae 24 V: 707 Vdc ab ingressu potentiae ad chassis Versio AC/DC et HVAC: 2200 Vdc ab ingressu potentiae ad chassis