page_banner

products

Dual Velocity Monitor

Description:

Item no: 3300/55-04-01-08-08-00-00-00-00

notam: Bent Nevada

pretium: $ DCCC

Delivery time: In Stock

Payment: T/T

shipping portum: xiamen


Product Detail

Product Tags

Descriptio

OPIFICIUM Bently Nevada
Exemplar 3300/55
Mandare informationes 3300/55-04-01-08-08-00-00-00-00
Catalogue 3300
Descriptio Dual Velocity Monitor
Origin United States (US)
HS Code* 85389091
Dimension 16cm*16cm*12cm
Pondus 0.8kg

Singula

Descriptio

Dual Velocitas Monitor 3300/55 duos canales machinis in-linearum continuarum vibrationum vigilantia praebet.Monitor inputationes accipit ab uno vel duobus transductoribus Velomitor®, Systems Velomitoris High Temperature (HTVS), vel Velocitas Seismoprobe® transducers sine necessitate modulorum interfaciendi.Flexibilitas in Dual Velocitate Monitor designatur.Multi optiones usorum selectabiles, ut summus et humilis-transitus colum anguli frequentiae optionum, facile (re) programmata sunt in campo cum obturaculum-in jumpers

Dual Velocitas Monitor 3300/55-AXX-BXX-CXX-DXX-EXX-FXX-GXX-HXX

A: Channel Input Option 0 1 Dual Velocitas Inputs: Canales A & B indicant velocitatis apicem.0 2 Dual Velocitas Inputs: Channel A indicat in cacumine velocitatis unitates, Channel B in cacumine obsessionem indicat.0 3 Dual Velocitas Inputs: canales A & B indicant obsessionem ad apicem.0 4 Dual Velocitas Inputs: Canales A & B indicant velocitatem in rms.0 5 Singula Velocitas Input: Canales A & B indicant velocitatis apicem.0 6 Velocitas unica Input: Channel A indicat in cacumine velocitatis unitates, Channel B in cacumine obsessionem indicat.0 7 Singula Velocitas Input: canales A & B indicant obsessionem ad apicem.0 8 Singula Velocitas Input: Canales A & B indicant velocitatem in rmat.

B: Transducer Type Option 0 1 9200 or 74712, 500 mV/in/s (2- filum, 10 kΩ input impedimentum).0 2 47633 vel 86205, 500 mV/in/s (2-filum, 24.9 kΩ input impedimentum) 0 3 145 mV/in/s (CEC 4-126) 0 4 Velomitor 100 mV/in/s 0 5 HTVS 145 mV /in/s Nota: Transductor intentionis eligendus est 24 Vdc in copia potentiae cum optio Velomitoris vel HTVS adhibetur.

C: Channel R plene Range Bene 0 1 0 - 0.5 in/s pk 0 2 0 - 1 in/s pk

0 3 0 - 2 in/s pk 0 4 0 - 5 mils pp 0 5 0 - 10 mils pp 0 6 0 - 20 mils pp 0 7 0 - 0.5 in/s rms 0 8 0 - 1 in/s rms 0 9 0 - 2 in/s rms 1 1 0 - 10 mm/s pk 1 2 0 - 20 mm/s pk 1 3 0 - 50 mm/s pk 1 4 0 - 100 µm pp 1 5 0 - 200 µm pp 1 6 0 - 500 µm pp 1 7 0 - 10 mm/s rms 1 8 0 - 20 mm/s rms 1 9 0 - 50 mm/s rms

D: Channel B in/s pk 0 1 0 - 0.5 in/s pk 0 2 0 - 1 in/s pk 0 3 0 - 2 in/s pk 0 4 0 - 5 mils pp 0 5 0 - 10 mils pp. 0 6 0 - 20 mils pp 0 7 0 - 0.5 in/s rms 0 8 0 - 1 in/s rms 0 9 0 - 2 in/s rms 1 1 0 - 10 mm/s pk 1 2 0 - 20 mm/ s pk 1 3 0 - 50 mm/s pk 1 4 0 - 100 µm pp 1 5 0 - 200 µm pp 1 6 0 - 500 µm pp 1 7 0 - 10 mm/s rms 1 8 0 - 20 mm/s rms 1 9 0 - 50 mm/s rms

E: Agency Approbatio Option 0 0 Non requiritur 0 1 CSA/NRTL/C 0 2 ATEX sui certificationis Nota: ATEX approbatio requirit monitor eculeum institui in tempestatibus pro habitatione.

F: Salus Intrinsica Claustra 0 0 Nullae 0 1 Externi (01, 02, 03 genera Transducer) 0 2 Interna (01, 02, 03 genera Transducer) 0 3 Externi (04, 05 genera Transducer) Notae: Salus externae claustra ordinari debent separatim.